Multi-parameter Patient Monitor

Item No.: BT-E035
Description
Techniacl specifications:
 
 Quality standards
CE, ISO13485
SFDA: Class II b
Anti-electroshock degree: Class I equipment 
                                     (internal power supply)
TEMP/Sp02 /NIBP: BF
ECG/Resp: CF
 Application Range
Adult/Pediatric/Neonatal/Medicine/Surgery/
Operating Room/ICU/CCU
 Display
12.1” real color TFT screen
 Environment
Operating environment:
Temperature:        0~40°C
Humdidty:            15%~80%
Pressure:             86.0kPa~106.0kPa
Transport and Storage environment:
Temperature:        -20~55°C
Humdidty:            10%~90%
Pressure:             86.0kPa~106.0kPa
 Power Requirements
AC: 100~240V,50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 11.1V 24wh Li-ion battery
            2h operating after full charge
            5min operating after low battery alarm
 Dimension and Weight
Equipment:
340mm*245mm*134mm; 2.798kg (about)
Package:
380mm*350mm*300mm; 4.598kg (about)
 Date Storage
Trend diagram/table:720h
NIBP review:    10000 events
Wave review:    12h
Alarm review:    200 alarm events
Support drug concentration titration analysis
 ECG
5 Leads: RA, LA, LL, RL, V
Lead mode: I, II, III, aVR, aVL, aVF, V
Gain: x1.25mm/mV, 2.5mm/mV, 5.0mm/mV,
         10mm/mV, 20mm/mV (error≤5%)
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s,
                    50mm/s (error≤±10%)
Bandwidth: Surgery 1~25Hz
                Monitor 0.5~40Hz
                Diagnostic 0.05~130Hz
Sensitivity: >200 μV P-P
CMRR: ≥112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential: ±300mV  
Polarization Voltage: ≥±500mV
Imput Impedance: ≥5M    
Calibrating Voltage: 1mV ±5%
 ST Segment
ST Segment range: -2.0mV~+2.0mV
Accuracy: 0.02mV
 SpO2
Measurement range: 0~100%
Resolution: 1%
Accuracy: 70%~100%: ±2%
               40%~69%: ±3% 
 Pluse Rate
Measure/alarm range: 20~300bpm
Resolution: 1bpm
Accuracy: ±3bpm
 RESP
Method: impedance between RA-LL
Resp Impedance range: 0.3~3Ω
Base Impedance range: 200Ω~4000Ω
Bandwidth: 0.3~2.5Hz
Gain: x0.25, x0.5, x1, x2, x4
Resp rate: 
Measurement Range
               Adult: 0~120BrPM
               Neonatal/Pediatric: 0~150BrPM
Resolution: 1BrPM
Accuracy: 7~150BrPM (±2BrPM)
              0~6BrPM (unspecified)
Apena Alarm: 10~40 seconds
 NIBP
Method: oscillometry
Work mode: Manual/Auto/STAT
Measure interval in auto mode:
1,2,3,4,5,10,15,30,60,90,120,180,240,480min
Measure period in STAT mode: 5min
Pulse rate range: 40~240bpm
Measure & alarm range: 
Adult:      SYS     40~280mmHg
              DIA      10~220mmHg
              MEAN  20~240mmHg
Pediatric: SYS     40~220mmHg
              DIA      10~160mmHg
              MEAN  20~170mmHg
Neonatal: SYS     40~135mmHg
              DIA      10~100mmHg
              MEAN  20~110mmHg
Static pressure measurement 
Range: 0~300mmHg
Accuracy: ±3mmHg
Resolution: 1mmHg Accuracy
Max. average error: ±5mmHg
Max. standard deviation: 8mmHg
Overvoltage protection: Adult       300mmHg
                                 Pediatric  240mmHg
                                 Neonatal  150mmHg
 TEMP
Channel: 2
Measure & alarm range: 0~50°C
Resolution: 0.1°C
Accuracy (no sensor): ±0.1°C (0~50°C)
 Standard accessories
· NIBP cuff & tube    
· ECG cable & electrodes
· SpO2 sensor          
· TEMP probe
· Lithium-ion battery 
· Power cable
· Operator’s manual 